117MAXDATA SR1202 M1 – StorView
®
RAID User Guide
Controller Events
Messages
Type [ID] Cause Action
The controllers internal
temperature <aa>C has
exceeded the maximum
limit. The controller will
shutdown to prevent
damage.
Error
[0xB03 (2819)]
Blocked fan.
Failing fan.
Elevated ambient
temperature.
Check enclosure for sufficient
air flow.
Check for a
failed fan, if found
replace cooling fan module.
Check the ambient tempera
-
ture of the environment,
decrease the local ambient
temperature.
The controllers
internal temperature
<aa>C is approaching
the maximum limit.
You should check the
cooling system for
problems.
Warning
[0xB04 (2820)]
Blocked fan.
Failing fan.
Elevated ambient
temperature.
Check enclosure for sufficient
air flow.
Check for a failed fan, if found
replace cooling fan module.
Check the ambient tempera
-
ture of the environment,
decrease the local ambient
temperature.
The onboard cache
protection battery
backup unit has failed
or has been discon-
nected.
Error
[0xB07 (2823)]
Battery failure. Replace battery in the
controller.
The partner controller
has failed or has been
removed.
Error
[0xB08 (2824)]
Failure or removal of
one controller (partner)
in an Active-Active
configuration.
Re-install the controller.
Replace the controller.
This controller has not
received a response
from the other (partner)
controller in the allotted
time, and therefore it
has been disabled.
Error
[0xB09 (2825)]
Failure or removal of
one controller (partner)
in an Active-Active
configuration.
Replace the controller.
An error has been
detected on the SAS
domain or with a SAS
device during the
discovery process.
Error
[0xB0F (2831)]
Possible drive or
internal bus error.
Replace drive.
The controllers <x>
voltage reading meas
-
ures <aa>V which
exceeds the limit.
Error
[0xB19 (2841)]
Voltage regulator hard
-
ware failure.
Enclosure 5 V or 12 V
problem in the power
supply.
Replace the controller.
Replace the defective power
supply.
Internal transfer error. Error
[0xB1A (2842)]
Hardware problem. Replace the controller.
The discovery process
has completed identi-
fying all SAS devices
on the SAS domain.
Information
[0xB22 (2850)]
Courtesy informational
message.
No action necessary.